Guide · Regulations
PAS 24 and Approved Document Q: what they mean for windows and doors
By Frazer Biggs, founder of Vitrova, 8 years in the glazing industry · ·
The short answer
Approved Document Q sets the security standard for doors and windows in new homes in England, including homes formed by a change of use; it does not apply to replacement windows in an existing home. Any door, and any window that is easily accessible, must resist being forced open, and the usual way to show that is a product tested to PAS 24. Approved Document Q names the 2012 edition; current products are tested to PAS 24:2016 or 2022. A window counts as easily accessible if any part of it is within 2 m vertically of the ground or another surface you can stand on, or within 2 m of a flat or low-pitched roof that is itself within 3.5 m of the ground. Where an easily accessible window has locks without keys, or sits within 400 mm of a door, its glass should be laminated to at least class P1A of BS EN 356. The frames must also be mechanically fixed to the building.
What is PAS 24?
PAS 24 is a British test of how well a door or window resists an attempt to break in using hand tools. A product passes as a complete set: the frame, sash, glass, locks and hinges as tested. Change one of those, for example by fitting different glass or hardware, and the result may no longer apply, which is why PAS 24 is specified on the order rather than added later. Approved Document Q (2015) names PAS 24:2012; products tested to the later 2016 and 2022 editions are what you will find today.
When does Approved Document Q apply?
Part Q applies to new dwellings, including dwellings formed by a change of use in England. It covers every door that gives access to the home, and every easily accessible window and rooflight. Replacing windows or doors in an existing home is notifiable building work, but Part Q itself doesn’t apply to it; many buyers still ask for PAS 24 for the security.
- Easily accessible: any part of the window within 2 m vertically of the ground, a basement level or an access balcony.
- Also easily accessible: within 2 m vertically of a flat or sloping roof (pitch under 30°) that is within 3.5 m of the ground.
- Laminated glass to BS EN 356 class P1A: where an easily accessible window has non-key locking hardware, or is within 400 mm of a door.
What the manufacturers state for our products
As each manufacturer states on its product data, and as shown on each product page. Ask for the test evidence with your quotation when a project relies on it.
| Product | The manufacturer states |
|---|---|
| Vitrova BiFold | PAS 24 with laminated P1A glass |
| Vitrova 4700 Sliding Door | PAS 24:2022 with laminated glass |
| Panoramic 20 Aluminium Sliding Door | PAS 24:2016 with the interlock deadbolt option |
| Signature Aluminium Casement Window | Tested to PAS 24:2016 (Exova (UK) Ltd, 2018); test details on request |
| Panoramic Fold 80 Aluminium Bifold Door | PAS 24 available (glass 28–46 mm, leaves 750–1,200 mm wide and 1,860–3,000 mm high) |
| Vitrova Heritage Sliding Sash Window | High-security locking; PAS 24 upgrade available |
| Vitrova Heritage Flush Window | Shoot-bolt multipoint locking with night vent; PAS 24 / Document Q available |
Questions people ask
Do replacement windows have to meet Part Q?
No. Approved Document Q applies to new dwellings, including those formed by a change of use. Replacement windows still need building regulations compliance for things like energy, safety glazing and ventilation.
What does P1A glass mean?
P1A is the lowest attack-resistance class in BS EN 356, met by laminated glass with an interlayer that holds the pane together when it breaks. Part Q asks for it in some easily accessible windows and next to doors.
Which edition of PAS 24 do I need?
Approved Document Q names PAS 24:2012. Products on sale today are tested to PAS 24:2016 or PAS 24:2022, which building control bodies generally accept; check with yours if in doubt.
Next steps
Sources
This guide covers England and is general information, not a substitute for advice from your building control body or planning authority on a particular project.