Part L U-values for replacement windows and doors
By Frazer Biggs, founder of Vitrova, 8 years in the glazing industry · ·
The short answer
In England, a replacement window in an existing home must have a U-value of no more than 1.4 W/m²K, or a Window Energy Rating of band B or better. That limit comes from Table 4.2 of Approved Document L, Volume 1 (2021 edition). Replacement doors must also reach 1.4 W/m²K, or a Doorset Energy Rating of band C if more than 60% of the inside face is glass and band B if not. Rooflights must reach 2.2 W/m²K. In a new home Table 4.1 sets 1.6 W/m²K for windows and doors and 2.2 for rooflights, though the home’s energy calculation usually needs better. The figure that counts is the whole-window U-value (Uw), which includes the frame, not the centre-pane value (Ug) printed on glass. Ask for the Uw at your size and glass, because it changes with both.
The limits in Approved Document L
These are the maximum U-values for new or replacement windows, doors and rooflights in dwellings in England. Lower is better.
| Element | Existing home (Table 4.2) | New home (Table 4.1) |
|---|---|---|
| Window | 1.4 W/m²K, or WER band B | 1.6 W/m²K |
| Door, more than 60% glazed | 1.4 W/m²K, or DSER band C | 1.6 W/m²K |
| Other door | 1.4 W/m²K, or DSER band B | 1.6 W/m²K |
| Rooflight | 2.2 W/m²K | 2.2 W/m²K |
Uw, Ug and the size the figure was tested at
Ug is the centre of the glass only. Uw is the whole window, frame included, and it is the figure Part L uses. Because aluminium frames lose more heat than glass, a small window with a lot of frame has a worse Uw than a large one in the same system. Manufacturers publish Uw at a standard test size; your window’s own figure can be a little better or worse.
Where a product meets the limit through an energy rating instead of a U-value, ask for the rating certificate with your quote so your installer or building control can see it.
How Vitrova’s windows and doors compare
Published figures for the systems we supply, against the 1.4 W/m²K limit for existing homes. Your quotation gives the figure for each opening at its size and glass.
| Product | Published figure | At |
|---|---|---|
| Signature Aluminium Casement Window, triple glazed | Uw 1.04 W/m²K | 1,440 × 1,330 mm |
| Signature Aluminium Casement Window, double glazed | Uw 1.44 W/m²K | 1,230 × 1,480 mm |
| Panoramic 35 Aluminium Sliding Door, triple glazed | Uw 1.17 W/m²K | 3,400 × 1,792 mm |
| Panoramic 35 Aluminium Sliding Door, double glazed | Uw 1.42 W/m²K | 3,400 × 1,792 mm |
| Panoramic 20 Aluminium Sliding Door, double glazed | Uw 1.47 W/m²K | 4,182 × 2,100 mm |
| Entrance Door Essential | Ud 1.16 W/m²K | single leaf 1,250 × 2,500 mm, inward |
| Entrance Door Signature | Ud 0.98 W/m²K | single leaf 1,250 × 2,500 mm, inward |
| Vitrova BiFold | From 1.6 W/m²K; DSER C | manufacturer’s brochure |
| Vitrova 4700 Sliding Door | DSER C | manufacturer’s brochure |
| Vitrova Heritage Sliding Sash Window | Uw 1.4 W/m²K (1.2 with upgraded glass) | manufacturer’s figure |
| Vitrova Heritage Flush Window | Uw 1.4 W/m²K (1.2 with upgraded glass) | manufacturer’s figure |
| Vitrova Aluminium Roof Lantern | Ug 1.2 W/m²K, or 1.0 W/m²K with premium glass | centre pane |
Listed buildings, conservation areas and period homes
Approved Document L accepts that full compliance isn’t always right for historic buildings. Where windows or fully glazed external doors can’t meet Table 4.2 without spoiling the character of the building, the guidance allows glass with a centre-pane U-value of no more than 1.2 W/m²K, or single glazing with low-emissivity secondary glazing. In listed buildings, conservation areas and scheduled monuments the work should still meet the standard as far as is reasonably practicable. Agree the approach with building control before ordering.
Who proves the window complies?
The installer does. An installer registered with a competent person scheme self-certifies the work and you receive a certificate; otherwise the work goes through building control. Vitrova’s quotation states the U-value or energy rating for each line so the installer has the evidence to hand.
Questions people ask
What U-value do replacement windows need in England?
1.4 W/m²K or better, or a Window Energy Rating of band B or better (Approved Document L, Volume 1, Table 4.2). The U-value is for the whole window, frame included.
Is double glazing still allowed for replacement windows?
Yes, if the whole window reaches 1.4 W/m²K or WER band B. Some aluminium double-glazed windows don’t at smaller sizes, which is why many aluminium windows are now supplied triple glazed.
Do the U-value rules apply in Wales and Scotland?
This guide covers England. Wales and Scotland publish their own building regulations guidance with their own figures; check the version for where the home is.
Next steps
Sources
This guide covers England and is general information, not a substitute for advice from your building control body or planning authority on a particular project.